HMO fire risk assessments: key facts
- GOV.UK: an HMO is a property rented out by at least 3 people who are not from 1 household but share facilities like the bathroom and kitchen.
- The Fire Safety Order applies to the common parts of HMOs. For shared areas, the landlord, freeholder or managing agent is the responsible person.
- The Housing Act 2004 applies to all HMOs and is enforced by the council, including licensing and the management regulations.
- England: a licence is mandatory for an HMO rented to 5 or more people forming more than 1 household who share facilities.
- Every HMO licence must include conditions on gas safety, electrical safety and smoke alarms; in England, carbon monoxide alarms too.
- LACORS guidance treats a shared house let to one group as often lower risk than a bedsit-type HMO.
Which fire safety laws apply to an HMO?
In England and Wales two regimes overlap. The Fire Safety Order covers the common parts and requires a fire risk assessment, enforced by the fire and rescue service. The Housing Act 2004 covers the whole house, including licensing and management duties, and is enforced by the council.
The Regulatory Reform (Fire Safety) Order 2005. The Home Office guide for people with duties says the Order applies to the common parts of HMOs, such as communal corridors and stairways, plus the structure, external walls and doors between each home and the common parts. The responsible person must make a suitable and sufficient fire risk assessment, record all its findings and keep it under review. The guide also notes that the common parts of an HMO still have a responsible person even though they aren't a workplace.
The Housing Act 2004. This applies to all HMOs and to the whole building, including the rooms people live in. It brings in:
- The Housing Health and Safety Rating System (HHSRS). In England its hazards include fire and explosions: exposure to uncontrolled fire and its smoke and fumes. GOV.UK says the council must carry out an HHSRS assessment of a licensed HMO within 5 years of the application, and you must fix any unacceptable risks it finds.
- HMO licensing, with conditions written into each licence.
- The HMO management regulations, which put day-to-day fire duties on the manager.
The Home Office factsheet on section 156 of the Building Safety Act notes that the Housing Act 2004 lists local authority enforcement in non-domestic parts of multi-occupied residential buildings. LACORS guidance calls this a dual enforcement regime, with a Fire Safety Protocol setting out how councils and fire and rescue authorities work together.
Who is responsible for fire safety in an HMO?
Usually the landlord. GOV.UK says the responsible person for common areas of multi-occupied residential buildings is the landlord, freeholder or managing agent. LACORS adds that where an absentee landlord leaves the running of the house to a managing agent, the agent may be the responsible person.
Responsibility is often shared:
- Managing agents. Anyone with control of the premises to any extent, or a contract to maintain or repair them, has duties under the Order for the matters within their control.
- The licence holder and manager. The licence holder must meet the licence conditions. GOV.UK says the manager, either you or an agent, must be "fit and proper". The management regulations put fire duties on the manager.
- Freeholders. Where the HMO is a flat inside a bigger building, the freeholder may be responsible for the stairs and structure outside it. Responsible persons must try to identify each other, share contact details and say which part each covers.
Tenants must co-operate too. The Home Office guide expects occupiers not to undermine fire safety, for example by blocking escape routes or wedging open fire doors to the common parts.
You can do the assessment yourself if you're competent. If you pay someone else, you must record their name, and you stay liable in law if the assessment isn't suitable and sufficient.
Is a shared house treated differently from a bedsit-type HMO?
Yes. LACORS guidance describes a shared house, let as a whole to one group on a single joint tenancy, as often lower risk than a bedsit-type HMO, where rooms are let separately to people living independently. For bedsits it usually expects a 30-minute protected escape route and fire doors to every risk room.
Both are HMOs in law and both can need a licence. But the main guidance, Housing – Fire Safety, published by LACORS in 2008 with a foreword from government ministers, draws a clear line between them.
| Shared house | Bedsit-type HMO | |
|---|---|---|
| How it's let | Whole house to one group (students, colleagues, friends) on a single joint tenancy | Separate lettings, each with its own tenancy and usually a lock on each door |
| How people live | Own bedrooms; share kitchen, living room and bathroom | Independently, often with no shared living room |
| Cooking | Shared kitchen | Often inside each bedsit |
| Escape route (normal risk) | Up to two storeys: no full 30-minute protected route or fire doors needed if construction is sound, doors close-fitting and the route avoids risk rooms. Three or four storeys: 30-minute protected route | 30-minute protected route with FD30S fire doors to all risk rooms, even at one or two storeys |
| Self-closers | Can be unnecessary in smaller low-risk shared houses | Always on fire doors |
Detection differs too. For a shared house of up to four storeys, LACORS recommends interlinked mains alarms with battery back-up in the escape route, plus detection in the kitchen, lounge and any risky cellar. For bedsits with their own cooking, it gives interlinked detection in the common areas, heat detectors in each bedsit and a separate smoke alarm in each bedsit to protect the person sleeping there.
LACORS says there's no legal definition of a shared house and each case is judged on its merits. A shared house can still need more if the layout is unusual or occupants are at higher risk, for example through limited mobility or drug or alcohol dependency.
Does your HMO need a licence, and what do the conditions say about fire?
In England, an HMO rented to 5 or more people forming more than 1 household, who share a toilet, bathroom or kitchen, must have a council licence. Councils can license smaller HMOs too. Every licence must include conditions on gas safety, electrical safety and smoke alarms.
The Licensing of Houses in Multiple Occupation (Prescribed Description) (England) Order 2018 makes an HMO licensable if five or more people live there in two or more households. There's no storey test in England. GOV.UK adds that a smaller HMO may still need a licence depending on the area, so check with your council.
Schedule 4 of the Housing Act 2004 lists conditions every HMO licence must include. The fire-related ones are:
- a gas safety certificate from the last 12 months, given to the council every year, if there's a gas supply;
- electrical appliances and furniture you provide kept safe, with a declaration on demand;
- in England, every electrical installation in proper working order and safe for continued use;
- in England, a working smoke alarm on each storey with a room used as living accommodation (bathrooms and toilets count);
- in England, a working carbon monoxide alarm in any living room, including a hall or landing, with a fixed combustion appliance other than a gas cooker;
- a declaration about the alarms' condition and position on demand.
GOV.UK says the council may add other conditions, you can appeal against them to the First-tier Tribunal, a licence lasts at most 5 years, and renting out an unlicensed HMO can mean an unlimited fine.
A fire risk assessment isn't itself a Schedule 4 condition. But a current assessment with a dated action plan is the clearest way to show the council your precautions match the risk.
How do the smoke and carbon monoxide alarm regulations apply to HMOs?
In England, the Smoke and Carbon Monoxide Alarm (England) Regulations 2015 apply to unlicensed HMOs. Licensed HMOs are exempt from most of them only because the same alarm duties are written into licence conditions instead.
Government guidance on the 2022 amendments says this directly. Either way, from 1 October 2022 a relevant landlord in England must:
- fit at least one smoke alarm on each storey with a room used as living accommodation;
- fit a carbon monoxide alarm in any such room containing a fixed combustion appliance (gas cookers excluded);
- repair or replace faulty alarms once told about them.
Alarms must be checked on the day a new tenancy begins. The guidance suggests the tenant signing the check-in inventory to confirm the test. Councils enforce, and failing to comply with a remedial notice can mean a fine of up to £5,000 per breach.
What does a fire risk assessor look at in an HMO?
Mainly whether everyone can get out if a fire starts while they're asleep: the route from each room to the front door, the doors and fire separation along it, detection and alarms, sources of fire in kitchens and rooms, and how well the house is managed.
- The escape route. Does each room lead out without passing through a risk room such as a kitchen or lounge? Is the construction sound?
- Inner rooms. A bedroom reached only through another room. LACORS says avoid it where possible; otherwise it needs an escape window or alternative exit, detection and a fire-resisting door between the rooms, with both rooms controlled by the same person.
- Doors. Fire doors where the guidance expects them, closing properly, not propped or wedged open.
- Detection. Type, coverage and interlinking against the layout, plus test records.
- Cooking. Where kitchens and any bedsit cookers sit relative to the exit. LACORS says cooking in a room should be away from the exit door wherever possible.
- Storage. Bikes, bins, post and belongings on stairs and landings. LACORS says escape routes need no storage on them.
- Cellars. LACORS notes these are often neglected, can hold meters and wiring, and a fire there quickly threatens the escape route above.
- Trailing leads across escape routes, alongside the electrical evidence your licence needs.
- E-bikes and e-scooters. The Office for Product Safety and Standards advises charging them in a safe place without blocking exits and unplugging the charger afterwards. Raise it with your assessor if tenants keep them in hallways.
- Tenant information. Whether tenants know what to do when the alarm sounds and how to report faults.
The assessor should also ask about the people living there, because sleeping occupants and anyone with limited mobility affect what's needed.
What must the HMO manager keep doing between assessments?
In England the HMO management regulations require the manager to keep all means of escape from fire free from obstruction and in good repair, keep fire alarms and firefighting equipment in good working order, and display escape notices where there are five or more occupiers.
Regulation 4 of the Management of Houses in Multiple Occupation (England) Regulations 2006 sets those duties, plus taking all reasonable measures to protect occupiers from injury given the house's design, structure and number of occupiers. LACORS describes these as management regulations for all HMOs, not only licensed ones.
LACORS lists points it expects in any acceptable fire risk assessment, including:
- regular checks that escape routes are clear, with no storage or trip hazards;
- fire doors never propped or wedged open, with damage and missing smoke seals repaired;
- mains smoke alarms tested monthly with the test button, and panel systems tested weekly and serviced by a competent person;
- without a resident landlord or caretaker, clear instructions for tenants on testing alarms in their rooms and reporting faults, with a prompt response from you;
- a property log book recording servicing, defects, false alarms and repairs.
Tenant information. LACORS says tenants should be told what to do when the alarm sounds, how to call the fire service and report defects, to keep escape routes clear and fire doors shut, and about smoking and cooking safety. The Home Office guide cites NFCC guidance that fire drills are not recommended for HMO residents, so this information matters more.
Reviews. Review the assessment regularly and especially after a significant change, such as switching from a joint tenancy to room lets, adding a bedroom, building works or a fire.
How should you prepare for an HMO fire risk assessment?
Gather your licence and conditions, gas, electrical and alarm records and any previous assessment. Arrange access to every room the assessor needs. Choose someone with experience of HMOs like yours.
- Licence and conditions, or confirmation you don't need one, plus any council inspection letters.
- Records: gas certificates, electrical reports, alarm tests and the log book.
- Tenancy set-up: one joint tenancy or room lets, and how many people live there.
- A floor plan or sketch showing bedrooms, kitchens and the route out.
- Access: give tenants proper notice that their room doors and alarms may be checked.
- The previous assessment and what you've done since.
Questions to ask an assessor:
- How many HMOs of my type have you assessed?
- Will you look inside bedsits or bedrooms, or only the common parts?
- Will the report reflect the LACORS guidance and my council's HMO standards?
- Will you separate legal requirements from good practice?
The Home Office prefers assessors who are third-party certificated or registered by a professional body, though this isn't currently a legal requirement. See choosing a fire risk assessor and what drives the cost.
What about HMOs in Wales, Scotland and Northern Ireland?
The Fire Safety Order covers HMO common parts in Wales too, but mandatory licensing there applies only to HMOs of three or more storeys. Scotland treats licensed HMOs as non-domestic premises under the Fire (Scotland) Act 2005. Northern Ireland requires HMO landlords to hold a council licence.
Wales. The Fire Safety Order and Housing Act licensing both apply. Under the Licensing of Houses in Multiple Occupation (Prescribed Descriptions) (Wales) Order 2006, a mandatory licence is needed where the HMO, or part of it, has three or more storeys and five or more people live there in two or more households. Councils can license others. Schedule 4 conditions on gas, appliances and smoke alarms apply, but not the England-only alarm, carbon monoxide and electrical installation conditions. Check with your council.
Scotland. The Scottish Government says non-domestic premises under Part 3 of the Fire (Scotland) Act 2005 include HMOs that require a licence, and its guidance for premises with sleeping accommodation covers all types of HMO. The dutyholder carries out a fire safety risk assessment and the Scottish Fire and Rescue Service enforces. Significant findings must be recorded where, among other cases, the premises need a licence.
Northern Ireland. nidirect describes an HMO as the main home for three or more people not in the same family, and says the landlord must have a council licence before renting it out. Fire safety law is separate, so check with your council and the Northern Ireland Fire and Rescue Service.
Related guides
HMO fire risk assessments: frequently asked questions
Do I need a fire risk assessment for an HMO?
In England and Wales the Fire Safety Order applies to the common parts of HMOs, so the responsible person, usually the landlord or managing agent, must have a suitable and sufficient fire risk assessment. LACORS guidance takes the view that a shared house let as a whole to one group falls outside the Order, but the Housing Act 2004 still applies.
Who enforces fire safety in an HMO?
Both the fire and rescue service and the council. The fire service enforces the Fire Safety Order in the common parts. The council enforces the Housing Act 2004, including licensing, the management regulations and the HHSRS.
How many people make an HMO licensable in England?
Five or more people forming more than one household who share toilet, bathroom or kitchen facilities. Councils can also license smaller HMOs, so check with yours.
Is HMO licensing different in Wales?
Yes. Mandatory licensing in Wales applies where the HMO, or part of it, has three or more storeys and five or more people live there in two or more households. Councils can license other HMOs too.
Does every bedroom in an HMO need a fire door?
There's no single rule. LACORS usually expects fire doors to all risk rooms in bedsit-type HMOs and in shared houses of three or four storeys, but accepts sound, close-fitting ordinary doors in low-risk shared houses of up to two storeys. Your assessment and council standards decide.
What alarms does an HMO need?
In England the legal minimum is a smoke alarm on every storey with living accommodation and a carbon monoxide alarm in rooms with a fixed combustion appliance other than a gas cooker. LACORS often recommends more, such as interlinked systems and detection in kitchens and bedsits.
Do HMO tenants have to do fire drills?
No. The Home Office guide cites NFCC guidance that fire drills are not recommended for HMO residents. Tenants should instead get clear information on what to do if the alarm sounds and how to report faults.
Can tenants keep bikes in the hallway?
In England the HMO manager must keep means of escape free from obstruction, and LACORS says there should be no storage on escape routes. For e-bikes and e-scooters, OPSS advises charging in a safe place without blocking exits.
Sources
We checked the facts on this page against these sources on 14 November 2026:
- GOV.UK: House in multiple occupation licence
- GOV.UK: Renting out your property – Houses in Multiple Occupation (HMO)
- Home Office: A guide for persons with duties under fire safety legislation
- Home Office: Check your fire safety responsibilities under section 156 of the Building Safety Act 2022
- LACORS: Housing – Fire Safety, guidance on fire safety provisions for certain types of existing housing (2008, hosted by CIEH)
- GOV.UK: Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 – guidance for landlords and tenants
- OPSS: Government Safety Message on e-bikes and e-scooters
- nidirect: Living in shared accommodation