Fire risk assessments for blocks of flats: key facts
- In a building with two or more flats, the Fire Safety Order applies to the structure, external walls and common parts, and to all doors between flats and common parts (England and Wales). It does not apply inside the flats.
- External walls include doors and windows in them and anything attached to the outside, including balconies. This came in with the Fire Safety Act 2021: 1 October 2021 in Wales, 16 May 2022 in England.
- GOV.UK says the responsible person for common areas is the landlord, freeholder or managing agent.
- In England, every block with common parts used to escape must display fire safety instructions and give residents fire door information when they move in and every 12 months.
- In England, blocks above 11 metres need communal fire door checks at least every 3 months and best endeavours to check flat entrance doors at least every 12 months, with records.
- High-rise blocks in England (at least 18 metres or seven storeys) also need an information box, plans, an external wall record, monthly checks and wayfinding signs.
- Official guidance for purpose-built blocks describes four types of assessment and says a non-destructive, common-parts Type 1 will normally be sufficient for most blocks.
Who is the responsible person for a block of flats?
Whoever has control of the common parts. GOV.UK names the landlord, freeholder or managing agent; official guidance for blocks adds residents' management companies and right to manage companies.
The Fire Safety Order places its duties on the responsible person. Outside a workplace, that is the person who has control of the premises in connection with a trade, business or other undertaking (for profit or not), or the owner if the person in control doesn't (article 3). In a block of flats, that is usually a company or organisation, not a named individual.
The Home Office guide Fire safety in purpose-built blocks of flats says the responsible person is typically the freeholder or landlord, but may be a residents' management company or a right to manage company. It says managing agents will normally be either a responsible person or another person having control, and the same duties apply to them either way.
Duties also fall on anyone else with control, so far as matters within their control (article 5(3)), including anyone with a contract or tenancy duty to maintain, repair or keep the premises safe (article 5(4)).
- Freeholder appoints a managing agent: the agent normally has duties for what it controls under its contract, alongside the freeholder's own duties.
- Residents' management company or right to manage company: often the body in control of the common parts, so often the responsible person.
- Shop, office or gym on the ground floor: that business is the responsible person for its own workplace. Each responsible person must take reasonably practicable steps to find the others, share a name and UK address for notices, say which part they're responsible for, and co-operate (article 22).
If you aren't sure, check the leases, the management agreement and any right to manage paperwork, and write down who does what. The local fire and rescue authority is the main enforcer; the Home Office also lists local housing authorities (Housing Act 2004) for the common parts of residential buildings.
What does a fire risk assessment for flats cover, and what does it leave out?
It covers the structure, external walls and common parts of the building, and every door between a flat and the common parts. It does not cover the inside of individual flats, which the Fire Safety Order treats as domestic premises.
The Fire Safety Order doesn't apply to domestic premises. But where a building contains two or more sets of domestic premises, article 6 says it does apply to:
- the building's structure and external walls, and any common parts;
- all doors between the flats and the common parts, which means flat entrance doors opening onto a corridor or stair;
- doors and windows in the external walls, and anything attached to the outside of those walls, including balconies.
The Fire Safety Act 2021 added this wording. It came into force on 1 October 2021 in Wales and 16 May 2022 in England. The flats guide dates from 2011, before this change, so read its comments on doors alongside the current text of article 6.
The Home Office guide puts it simply: in multi-dwelling premises, only the flats themselves fall outside the Order. So expect the assessor to look at escape routes, compartmentation between flats and common parts (including risers and ceiling voids where they can be opened), a sample of flat entrance doors, communal fire doors, external walls and balconies, bin stores and plant rooms, firefighting equipment such as dry risers, and how fire safety is managed.
For external walls, the Fire Sector Federation guide notes you may need an assessor with knowledge of external wall systems, or for complex cases a qualified engineer. Agree this in the scope.
What extra duties apply in England, by building height?
The Fire Safety (England) Regulations 2022 set duties in three tiers: some apply to every block with common parts used to escape, more apply above 11 metres, and the most apply to high-rise blocks of at least 18 metres or seven storeys. They apply in England only and have been in force since 23 January 2023.
The regulations add tasks on top of the fire risk assessment; they don't replace it. Height is measured to the top storey (Approved Document B, Appendix D), and storeys below ground are ignored.
| Duty | Which blocks | Regulation |
|---|---|---|
| Display fire safety instructions (evacuation strategy, how to report a fire, what to do). Copy to new residents and to all residents every 12 months. | Every block with two or more flats and common parts residents would use to evacuate | Reg 9 |
| Tell residents to keep fire doors shut, not tamper with self-closers and report faults immediately. New residents and every 12 months. | Same as above | Reg 10(1) to (3) |
| Check communal fire doors at least every 3 months, including that self-closers work. | Above 11 metres | Reg 10(6), (7) |
| Use best endeavours to check flat entrance doors at least every 12 months, including self-closers. Record the steps taken, including attempts to get access. | Above 11 metres | Reg 10(4), (5), (7) |
| Secure information box for the fire and rescue service, with the responsible person's UK contact details and plans. Inspect at least annually. | High-rise: at least 18 metres or at least seven storeys | Reg 4 |
| Record of external wall design and materials, including the risk level from the fire risk assessment and mitigating steps. | High-rise | Reg 5 |
| Floor plans and a single-page building plan, with hard copies in the box. | High-rise | Reg 6 |
| Monthly checks of firefighting and evacuation lifts and essential firefighting equipment. Report faults not fixed within 24 hours to the fire and rescue service. Records accessible to residents. | High-rise | Reg 7 |
| Wayfinding signs showing floor and flat numbers, visible in low light. | High-rise | Reg 8 |
| Send the external wall record and the plans to the local fire and rescue service electronically. | High-rise | Reg 11 |
Easy to miss: a block under 18 metres with seven or more storeys is still high-rise, and the reg 9 and 10 information duties apply to small blocks with a shared stair too.
What must you record and tell residents since October 2023?
Since 1 October 2023, in England and Wales, the responsible person must record the whole fire risk assessment, record who carried it out, and give residents of buildings with two or more flats clear information about the fire risks and the measures in place.
Section 156 of the Building Safety Act 2022 changed the Fire Safety Order from 1 October 2023 (England and Wales):
- Full written record. Record all the findings, including measures taken or planned and anyone especially at risk (article 9(6), (7)).
- Assessor's identity. If someone helps you make or review the assessment, record their name and organisation.
- Information for residents (article 21A). Give residents understandable information on the risks found, the measures in place, your name and UK address, who helped with the assessment and anyone nominated for firefighting.
- Co-operation. Find any other responsible persons and share contact details (article 22).
- Handover. When the freehold is sold or management changes, the outgoing responsible person passes on assessment records, the assessor's identity and other key information (article 22A; in Wales commenced only for specified purposes so far).
In England, the reg 9 and reg 10 notices cover much of this, but article 21A also asks for the risks and measures from the assessment itself.
- The current fire risk assessment, earlier versions and the action plan with dates completed.
- Who carried out the assessment, and how you chose them.
- Copies of resident information and when it went out (new residents and every 12 months in England).
- Door check records, including refused access (above 11 metres in England).
Why are flat entrance doors the hardest part to manage?
Flat entrance doors protect the escape route from a fire inside a flat and are within the Fire Safety Order, but under many leases the door belongs to the leaseholder, so the freeholder may not control it.
The flats guide calls flat entrance doors "critical to the safety of the common parts in the event of a fire within a flat". They must be self-closing and adequately fire-resisting. Fitting suitable self-closers is "an essential short-term measure"; whether to upgrade or replace an older door depends on the risk.
The difficulty is ownership. Under many leases the door is part of the flat, so the leaseholder maintains it and the landlord may have no right to force an upgrade. The guide suggests leaseholders may then be other persons with control under article 5(3); in an impasse, refer it to the enforcing authority.
- Check each lease for who owns and maintains the door.
- Plan the checks. Above 11 metres in England, use best endeavours to check every flat entrance door at least every 12 months, including the self-closer. Write, offer times and record each attempt.
- Record refusals. The duty is best endeavours, so the record of what you tried matters.
Should a block have a stay put or a simultaneous evacuation strategy?
Official guidance says purpose-built blocks may adopt stay put, where only the flat on fire evacuates. Simultaneous evacuation needs a fire alarm and is sometimes used in converted blocks where compartmentation falls short.
Under a stay put strategy, as the flats guide describes it, people in the flat where the fire starts leave and call the fire and rescue service. Everyone else is expected to stay in their flat unless the fire or smoke affects them or the fire and rescue service tells them to leave. The Article 50 guide adds that this doesn't stop anyone choosing to leave at any time.
Stay put relies on good compartmentation. The flats guide says abandoning it simply because compartmentation is hard to verify should be questioned.
Simultaneous evacuation means getting the residents of a number of flats out together. It needs a fire detection and alarm system, which the flats guide says purpose-built blocks don't normally have. It is sometimes used in converted blocks where stay put compartmentation can't be achieved.
Which type of fire risk assessment does a block of flats need?
The official guide for purpose-built blocks describes four types: Type 1 (common parts, non-destructive), Type 2 (common parts, destructive), Type 3 (common parts and flats, non-destructive) and Type 4 (common parts and flats, destructive). It says Type 1 will normally be sufficient for most blocks.
The guide Fire safety in purpose-built blocks of flats was produced in 2011 by the Local Government Group (now the Local Government Association) and is published on GOV.UK under Article 50 of the Fire Safety Order. GOV.UK says it should be viewed as no longer comprehensive and that the Home Office is revising it. It sets out four types.
| Type | Scope | When the guide says it fits |
|---|---|---|
| Type 1: common parts, non-destructive | The basic assessment for the Fire Safety Order. Includes a sample of flat entrance doors and, without opening up, the construction between flats and common parts. | Normally sufficient for most purpose-built blocks, unless there's reason to expect serious problems with compartmentation or fire stopping. |
| Type 2: common parts, destructive | As Type 1, plus sample opening up of construction by a contractor. | A one-off, only with good reason to suspect serious structural deficiencies. Age alone isn't generally enough. |
| Type 3: common parts and flats, non-destructive | As Type 1, plus means of escape and smoke alarms inside a sample of flats. Goes beyond the scope of the Fire Safety Order. | Sometimes for rented flats with reason to suspect serious risk. Not possible for long leasehold flats without a right of access. |
| Type 4: common parts and flats, destructive | As Type 3, with destructive sampling in common parts and flats. | Limited cases, such as a new landlord taking over a block with an unknown history of works. |
When commissioning, the guide says to specify the type, give the assessor building information, help arrange access to a sample of flats and, for destructive types, expect to hire a contractor (and consider asbestos first).
What changes in a higher-risk building with accountable persons?
A higher-risk building under the Building Safety Act is at least 18 metres or seven storeys with at least two residential units. Its responsible person must take reasonably practicable steps to identify the accountable persons and co-operate with them (Fire Safety Order article 22B).
Tall blocks also fall under the Building Safety Act 2022, run by accountable persons: anyone with an obligation to repair any of the common parts, typically the freeholder or landlord (Home Office s156 factsheet). Where there are several, whoever owns or must repair the structure and exterior is the principal accountable person.
Under article 22B (England and Wales), the responsible person must co-operate with each accountable person so they can carry out their duties; the factsheet's example is sharing your fire risk assessment.
The same organisation may be both responsible person and accountable person. Where they differ, agree in writing who holds the assessment, commissions reviews and updates the high-rise records.
What should you prepare before a fire risk assessor visits a block?
Gather building information, the previous assessment and action plan, service records, lease details on doors and resident information. Agree the scope in writing and arrange access to plant rooms, risers and a sample of flats.
The Home Office says that if you can't do it yourself, it strongly recommends a professional fire risk assessor who is competent for your type of premises. Its example: offices and shops experience may not be enough for a high-rise block. The assessor competence rule (article 9A) is not yet in force, but you're liable if the assessment isn't suitable and sufficient. For small blocks, the Home Office publishes a simpler guide, Making your small block of flats safe from fire, for purpose-built or converted blocks of no more than a ground and two upper floors and no more than six flats.
- Height to the top storey, number of storeys and flats, and whether there are commercial units.
- Previous fire risk assessment, action plan and evidence of what has been done.
- Plans, regulation 38 information and any external wall surveys.
- Service records for the fire alarm (if any), emergency lighting, smoke ventilation, dry or wet risers and lifts.
- Lease clauses on who owns flat entrance doors, and records of door checks.
- Copies of resident fire safety instructions and when they were issued.
- Keys or codes for plant rooms, bin stores, meter cupboards, risers and the roof, and arranged access to a sample of flats.
Questions to ask the assessor: which type of assessment they propose and why; how many flat entrance doors they'll sample; whether external walls are in scope or need a specialist; how they'll rate and prioritise actions; and how often they recommend review. The law sets no fixed interval; the Home Office says your assessor should advise.
Compare quotes on the same scope: type, doors sampled and external walls.
How do the rules differ in Wales, Scotland and Northern Ireland?
Wales follows the Fire Safety Order like England but not the Fire Safety (England) Regulations 2022. In Scotland, Part 3 of the Fire (Scotland) Act 2005 generally does not apply to the common areas of blocks of flats. Northern Ireland has its own legislation.
Wales. The Fire Safety Order applies, including the Fire Safety Act 2021 changes (from 1 October 2021) and the s156 changes from 1 October 2023. The Fire Safety (England) Regulations 2022 don't apply, so the table above isn't a legal checklist in Wales, though the assessment still has to be suitable and sufficient.
Scotland. Part 3 of the Fire (Scotland) Act 2005 doesn't apply to domestic premises, and the Act defines domestic premises to include a stair or passage used in common by the occupants of more than one dwelling (section 78), with exceptions such as licensable HMOs. The Scottish Government's practical guidance for existing high rise domestic buildings says a fire safety risk assessment is not legally required under Part 3 for the common areas of domestic premises, and that Part 3 does not generally apply to individual flats or the common areas of blocks of flats, though it may apply to some parts of a high rise building. It still recommends that those managing high rise blocks assess fire risk.
Northern Ireland. Fire safety law is the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010. Check the position for your block with the Northern Ireland Fire and Rescue Service.
Related guides
Fire risk assessments for blocks of flats: frequently asked questions
Is a fire risk assessment a legal requirement for a block of flats?
In England and Wales, yes, for the common parts, structure, external walls and flat entrance doors of any building with two or more flats. Scotland and Northern Ireland have different rules.
Who is responsible for the fire risk assessment in a leasehold block?
Usually whoever controls the common parts: the freeholder, a residents' management company or right to manage company, often with a managing agent who shares duties for what it controls.
Are leaseholders responsible for their flat entrance doors?
It depends on the lease. Official guidance notes that under many leases the door is part of the flat and the leaseholder maintains it, which limits what the freeholder can do. The freeholder still has to assess the risk, inform residents and, in England above 11 metres, use best endeavours to check the doors every year.
How often should flat entrance doors be checked?
In England, in blocks above 11 metres, the responsible person must use best endeavours to check them at least every 12 months and record the steps taken, including failed attempts to get access.
How often should a fire risk assessment for a block of flats be reviewed?
The law requires regular review and a review whenever the assessment may no longer be valid or there has been a significant change. No fixed interval is set, and the Home Office says your fire risk assessor should advise you on frequency.
What is a Type 1 fire risk assessment?
It is the basic, non-destructive assessment of the common parts described in official guidance for purpose-built blocks, including a sample of flat entrance doors. The guidance says it will normally be sufficient for most purpose-built blocks unless there is reason to suspect serious problems.
Do residents have a right to see fire safety information?
Since 1 October 2023, in England and Wales, the responsible person must give residents understandable information on the risks found, the safety measures, their name and UK address, and who helped with the assessment.
What happens if the responsible person ignores the assessment?
The local fire and rescue authority can give advice and issue informal notices, alterations, enforcement or prohibition notices. Failing to meet the duties where it puts people at risk of death or serious injury is an offence, with an unlimited fine or up to two years in prison on indictment.
Sources
We checked the facts on this page against these sources on 14 November 2026:
- Home Office: Fire safety in purpose-built blocks of flats (GOV.UK)
- Home Office: A guide for persons with duties under fire safety legislation
- Home Office: Check your fire safety responsibilities under section 156 of the Building Safety Act 2022
- GOV.UK: Fire safety in the workplace: who's responsible
- Fire Safety (England) Regulations 2022 (legislation.gov.uk)
- Scottish Government: Fire safety - existing high rise domestic buildings: practical guidance
- Fire Sector Federation: A Guide to Choosing a Competent Fire Risk Assessor (NFCC)